Area
PowerSystems.Area — Type
mutable struct Area <: AggregationTopology
name::String
peak_active_power::Float64
peak_reactive_power::Float64
load_response::Float64
ext::Dict{String, Any}
internal::InfrastructureSystemsInternal
endA collection of buses for control purposes.
The Area can be specified when defining each ACBus or DCBus in the area
Arguments
name::String: Name of the component. Components of the same type (e.g.,PowerLoad) must have unique names, but components of different types (e.g.,PowerLoadandACBus) can have the same namepeak_active_power::Float64: (default:0.0) Peak active power in the areapeak_reactive_power::Float64: (default:0.0) Peak reactive power in the areaload_response::Float64: (default:0.0) Load-frequency damping parameter modeling how much the load in the area changes due to changes in frequency (MW/Hz). Example here.ext::Dict{String, Any}: (default:Dict{String, Any}()) An extra dictionary for users to add metadata that are not used in simulation.internal::InfrastructureSystemsInternal: (Do not modify.) PowerSystems.jl internal reference