Transformer2W

PowerSystems.Transformer2WType
mutable struct Transformer2W <: ACTransmission
    name::String
    available::Bool
    active_power_flow::Float64
    reactive_power_flow::Float64
    arc::Arc
    r::Float64
    x::Float64
    primary_shunt::Float64
    rating::Union{Nothing, Float64}
    base_power::Float64
    rating_b::Union{Nothing, Float64}
    rating_c::Union{Nothing, Float64}
    services::Vector{Service}
    ext::Dict{String, Any}
    internal::InfrastructureSystemsInternal
end

A basic 2-winding transformer.

The model uses an equivalent circuit assuming the impedance is on the High Voltage Side of the transformer. The model allocates the iron losses and magnetizing susceptance to the primary side

Arguments

  • name::String: Name of the component. Components of the same type (e.g., PowerLoad) must have unique names, but components of different types (e.g., PowerLoad and ACBus) can have the same name
  • available::Bool: Indicator of whether the component is connected and online (true) or disconnected, offline, or down (false). Unavailable components are excluded during simulations
  • active_power_flow::Float64: Initial condition of active power flow through the transformer (MW)
  • reactive_power_flow::Float64: Initial condition of reactive power flow through the transformer (MVAR)
  • arc::Arc: An Arc defining this transformer from a bus to another bus
  • r::Float64: Resistance in pu (SYSTEM_BASE), validation range: (-2, 4)
  • x::Float64: Reactance in pu (SYSTEM_BASE), validation range: (-2, 4)
  • primary_shunt::Float64: Shunt reactance in pu (SYSTEM_BASE), validation range: (0, 2)
  • rating::Union{Nothing, Float64}: Thermal rating (MVA). Flow through the transformer must be between -rating and rating. When defining a transformer before it is attached to a System, rating must be in pu (SYSTEM_BASE) using the base power of the System it will be attached to, validation range: (0, nothing)
  • base_power::Float64: Base power (MVA) for per unitization, validation range: (0, nothing)
  • rating_b::Union{Nothing, Float64}: (default: nothing) Second current rating; entered in MVA.
  • rating_c::Union{Nothing, Float64}: (default: nothing) Third current rating; entered in MVA.
  • services::Vector{Service}: (default: Device[]) Services that this device contributes to
  • ext::Dict{String, Any}: (default: Dict{String, Any}()) An extra dictionary for users to add metadata that are not used in simulation.
  • internal::InfrastructureSystemsInternal: (Do not modify.) PowerSystems.jl internal reference
source