DynamicGenerator
PowerSystems.DynamicGenerator — Typemutable struct DynamicGenerator{
M <: Machine,
S <: Shaft,
A <: AVR,
TG <: TurbineGov,
P <: PSS,
} <: DynamicInjection
name::String
ω_ref::Float64
machine::M
shaft::S
avr::A
prime_mover::TG
pss::P
base_power::Float64
n_states::Int
states::Vector{Symbol}
ext::Dict{String, Any}
internal::InfrastructureSystemsInternal
endA dynamic generator with the necessary data for modeling the dynamic response of a generator in a phasor or electromagnetic transient simulation.
Dynamic generator is composed by 5 components, namely a Machine, a Shaft, an Automatic Voltage Regulator (AVR), a Prime Mover and Turbine Governor, and Power System Stabilizer (PSS). It must be attached to a StaticInjection device using add_component!, which contains all the rest of the generator's data that isn't specific to its dynamic response.
Arguments
name::String: Name of generator.ω_ref::Float64: Frequency reference set-point in pu.machine <: Machine: Machine model for modeling the electro-magnetic phenomena.shaft <: Shaft: Shaft model for modeling the electro-mechanical phenomena.avr <: AVR: AVR model of the excitacion system.prime_mover <: TurbineGov: Prime Mover and Turbine Governor model for mechanical power.pss <: PSS: PSS model.base_power::Float64: (default:100.0) Base power of the unit (MVA) for per unitization. Although this has a default, in almost all casesbase_powershould be updated to equal thebase_powerfield of theStaticInjectiondevice that this dynamic generator will be attached to.n_states::Int: (Do not modify.) Number of states (will depend on the inputs above).states::Vector{Symbol}: (Do not modify.) Vector of states (will depend on the inputs above).ext::Dict{String, Any}: (default:Dict{String, Any}()) An extra dictionary for users to add metadata that are not used in simulationinternal::InfrastructureSystemsInternal: (Do not modify.) PowerSystems.jl internal reference