TwoTerminalVSCDCLine
PowerSystems.TwoTerminalVSCDCLine
— Typemutable struct TwoTerminalVSCDCLine <: ACBranch
name::String
available::Bool
active_power_flow::Float64
arc::Arc
rectifier_tap_limits::MinMax
rectifier_xrc::Float64
rectifier_firing_angle::MinMax
inverter_tap_limits::MinMax
inverter_xrc::Float64
inverter_extinction_angle::MinMax
services::Vector{Service}
ext::Dict{String, Any}
internal::InfrastructureSystemsInternal
end
A Voltage Sourced Converter (VSC)-HVDC transmission line.
As implemented in "Power System Modelling and Scripting" by Federico Milano, Chapter 18, Page 397. This model is suitable for dynamic simulations
Arguments
name::String
: Name of the component. Components of the same type (e.g.,PowerLoad
) must have unique names, but components of different types (e.g.,PowerLoad
andACBus
) can have the same nameavailable::Bool
: Indicator of whether the component is connected and online (true
) or disconnected, offline, or down (false
). Unavailable components are excluded during simulationsactive_power_flow::Float64
: Initial condition of active power flow on the line (MW)arc::Arc
: AnArc
defining this linefrom
a busto
another busrectifier_tap_limits::MinMax
: Minimum and maximum rectifier tap limits as a ratio between the primary and secondary side voltagesrectifier_xrc::Float64
: Rectifier commutation reactance in p.u. (DEVICE_BASE
)rectifier_firing_angle::MinMax
: Minimum and maximum rectifier firing angle (α) (radians)inverter_tap_limits::MinMax
: Minimum and maximum inverter tap limits as a ratio between the primary and secondary side voltagesinverter_xrc::Float64
: Inverter commutation reactance in p.u. (DEVICE_BASE
)inverter_extinction_angle::MinMax
: Minimum and maximum inverter extinction angle (γ) (radians)services::Vector{Service}
: (default:Device[]
) Services that this device contributes toext::Dict{String, Any}
: (default:Dict{String, Any}()
) An extra dictionary for users to add metadata that are not used in simulation, such as latitude and longitude.internal::InfrastructureSystemsInternal
: (Do not modify.) PowerSystems.jl internal reference
InfrastructureSystems.get_name
— Methodget_name(value::TwoTerminalVSCDCLine) -> String
Get TwoTerminalVSCDCLine
name
.
PowerSystems.get_active_power_flow
— Methodget_active_power_flow(value::TwoTerminalVSCDCLine) -> Any
Get TwoTerminalVSCDCLine
active_power_flow
.
PowerSystems.get_arc
— Methodget_arc(value::TwoTerminalVSCDCLine) -> Arc
Get TwoTerminalVSCDCLine
arc
.
PowerSystems.get_available
— Methodget_available(value::TwoTerminalVSCDCLine) -> Bool
Get TwoTerminalVSCDCLine
available
.
PowerSystems.get_ext
— Methodget_ext(value::TwoTerminalVSCDCLine) -> Dict{String, Any}
Get TwoTerminalVSCDCLine
ext
.
PowerSystems.get_inverter_extinction_angle
— Methodget_inverter_extinction_angle(
value::TwoTerminalVSCDCLine
) -> @NamedTuple{min::Float64, max::Float64}
Get TwoTerminalVSCDCLine
inverter_extinction_angle
.
PowerSystems.get_inverter_tap_limits
— Methodget_inverter_tap_limits(
value::TwoTerminalVSCDCLine
) -> @NamedTuple{min::Float64, max::Float64}
Get TwoTerminalVSCDCLine
inverter_tap_limits
.
PowerSystems.get_inverter_xrc
— Methodget_inverter_xrc(value::TwoTerminalVSCDCLine) -> Float64
Get TwoTerminalVSCDCLine
inverter_xrc
.
PowerSystems.get_rectifier_firing_angle
— Methodget_rectifier_firing_angle(
value::TwoTerminalVSCDCLine
) -> @NamedTuple{min::Float64, max::Float64}
Get TwoTerminalVSCDCLine
rectifier_firing_angle
.
PowerSystems.get_rectifier_tap_limits
— Methodget_rectifier_tap_limits(
value::TwoTerminalVSCDCLine
) -> @NamedTuple{min::Float64, max::Float64}
Get TwoTerminalVSCDCLine
rectifier_tap_limits
.
PowerSystems.get_rectifier_xrc
— Methodget_rectifier_xrc(value::TwoTerminalVSCDCLine) -> Float64
Get TwoTerminalVSCDCLine
rectifier_xrc
.
PowerSystems.get_services
— Methodget_services(value::TwoTerminalVSCDCLine) -> Vector{Service}
Get TwoTerminalVSCDCLine
services
.
PowerSystems.set_active_power_flow!
— Methodset_active_power_flow!(
value::TwoTerminalVSCDCLine,
val
) -> Any
Set TwoTerminalVSCDCLine
active_power_flow
.
PowerSystems.set_arc!
— Methodset_arc!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
arc
.
PowerSystems.set_available!
— Methodset_available!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
available
.
PowerSystems.set_ext!
— Methodset_ext!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
ext
.
PowerSystems.set_inverter_extinction_angle!
— Methodset_inverter_extinction_angle!(
value::TwoTerminalVSCDCLine,
val
) -> Any
Set TwoTerminalVSCDCLine
inverter_extinction_angle
.
PowerSystems.set_inverter_tap_limits!
— Methodset_inverter_tap_limits!(
value::TwoTerminalVSCDCLine,
val
) -> Any
Set TwoTerminalVSCDCLine
inverter_tap_limits
.
PowerSystems.set_inverter_xrc!
— Methodset_inverter_xrc!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
inverter_xrc
.
PowerSystems.set_rectifier_firing_angle!
— Methodset_rectifier_firing_angle!(
value::TwoTerminalVSCDCLine,
val
) -> Any
Set TwoTerminalVSCDCLine
rectifier_firing_angle
.
PowerSystems.set_rectifier_tap_limits!
— Methodset_rectifier_tap_limits!(
value::TwoTerminalVSCDCLine,
val
) -> Any
Set TwoTerminalVSCDCLine
rectifier_tap_limits
.
PowerSystems.set_rectifier_xrc!
— Methodset_rectifier_xrc!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
rectifier_xrc
.
PowerSystems.set_services!
— Methodset_services!(value::TwoTerminalVSCDCLine, val) -> Any
Set TwoTerminalVSCDCLine
services
.