ThermalMultiStart
PowerSystems.ThermalMultiStart — Typemutable struct ThermalMultiStart <: ThermalGen
name::String
available::Bool
status::Bool
bus::Bus
active_power::Float64
reactive_power::Float64
rating::Float64
prime_mover::PrimeMovers
fuel::ThermalFuels
active_power_limits::NamedTuple{(:min, :max), Tuple{Float64, Float64}}
reactive_power_limits::Union{Nothing, Min_Max}
ramp_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
power_trajectory::Union{Nothing, NamedTuple{(:startup, :shutdown), Tuple{Float64, Float64}}}
time_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
start_time_limits::Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}
start_types::Int
operation_cost::OperationalCost
base_power::Float64
services::Vector{Service}
time_at_status::Float64
must_run::Bool
dynamic_injector::Union{Nothing, DynamicInjection}
ext::Dict{String, Any}
time_series_container::InfrastructureSystems.TimeSeriesContainer
internal::InfrastructureSystemsInternal
endData Structure for thermal generation technologies.
Arguments
name::Stringavailable::Boolstatus::Boolbus::Busactive_power::Float64, validation range:active_power_limits, action if invalid:warnreactive_power::Float64, validation range:reactive_power_limits, action if invalid:warnrating::Float64: Thermal limited MVA Power Output of the unit. <= Capacity, validation range:(0, nothing), action if invalid:errorprime_mover::PrimeMovers: Prime mover technology according to EIA 923fuel::ThermalFuels: Prime mover fuel according to EIA 923active_power_limits::NamedTuple{(:min, :max), Tuple{Float64, Float64}}reactive_power_limits::Union{Nothing, Min_Max}ramp_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}, validation range:(0, nothing), action if invalid:errorpower_trajectory::Union{Nothing, NamedTuple{(:startup, :shutdown), Tuple{Float64, Float64}}}: Power trajectory the unit will take during the start-up and shut-down ramp process, validation range:(0, nothing), action if invalid:errortime_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}: Minimum up and Minimum down time limits in hours, validation range:(0, nothing), action if invalid:errorstart_time_limits::Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}: Time limits for start-up based on turbine temperature in hoursstart_types::Int: Number of start-up based on turbine temperature, validation range:(1, 3), action if invalid:erroroperation_cost::OperationalCostbase_power::Float64: Base power of the unit in MVA, validation range:(0, nothing), action if invalid:warnservices::Vector{Service}: Services that this device contributes totime_at_status::Float64must_run::Booldynamic_injector::Union{Nothing, DynamicInjection}: corresponding dynamic injection deviceext::Dict{String, Any}time_series_container::InfrastructureSystems.TimeSeriesContainer: internal time_series storageinternal::InfrastructureSystemsInternal: power system internal reference, do not modify
InfrastructureSystems.get_name — Methodget_name(value::ThermalMultiStart) -> String
Get ThermalMultiStart name.
InfrastructureSystems.get_time_series_container — Methodget_time_series_container(value::ThermalMultiStart) -> InfrastructureSystems.TimeSeriesContainer
Get ThermalMultiStart time_series_container.
InfrastructureSystems.set_name! — Methodset_name!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart name.
PowerSystems.get_active_power — Methodget_active_power(value::ThermalMultiStart) -> Any
Get ThermalMultiStart active_power.
PowerSystems.get_active_power_limits — Methodget_active_power_limits(value::ThermalMultiStart) -> NamedTuple{(:min, :max), _A} where _A<:Tuple{Any, Any}
Get ThermalMultiStart active_power_limits.
PowerSystems.get_available — Methodget_available(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart available.
PowerSystems.get_base_power — Methodget_base_power(value::ThermalMultiStart) -> Float64
Get ThermalMultiStart base_power.
PowerSystems.get_bus — Methodget_bus(value::ThermalMultiStart) -> Bus
Get ThermalMultiStart bus.
PowerSystems.get_dynamic_injector — Methodget_dynamic_injector(value::ThermalMultiStart) -> Union{Nothing, DynamicInjection}
Get ThermalMultiStart dynamic_injector.
PowerSystems.get_ext — Methodget_ext(value::ThermalMultiStart) -> Dict{String, Any}
Get ThermalMultiStart ext.
PowerSystems.get_fuel — Methodget_fuel(value::ThermalMultiStart) -> ThermalFuels
Get ThermalMultiStart fuel.
PowerSystems.get_must_run — Methodget_must_run(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart must_run.
PowerSystems.get_operation_cost — Methodget_operation_cost(value::ThermalMultiStart) -> PowerSystems.OperationalCost
Get ThermalMultiStart operation_cost.
PowerSystems.get_power_trajectory — Methodget_power_trajectory(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:startup, :shutdown), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart power_trajectory.
PowerSystems.get_prime_mover — Methodget_prime_mover(value::ThermalMultiStart) -> PrimeMovers
Get ThermalMultiStart prime_mover.
PowerSystems.get_ramp_limits — Methodget_ramp_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:up, :down), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart ramp_limits.
PowerSystems.get_rating — Methodget_rating(value::ThermalMultiStart) -> Any
Get ThermalMultiStart rating.
PowerSystems.get_reactive_power — Methodget_reactive_power(value::ThermalMultiStart) -> Any
Get ThermalMultiStart reactive_power.
PowerSystems.get_reactive_power_limits — Methodget_reactive_power_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:min, :max), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart reactive_power_limits.
PowerSystems.get_services — Methodget_services(value::ThermalMultiStart) -> Vector{Service}
Get ThermalMultiStart services.
PowerSystems.get_start_time_limits — Methodget_start_time_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}
Get ThermalMultiStart start_time_limits.
PowerSystems.get_start_types — Methodget_start_types(value::ThermalMultiStart) -> Int64
Get ThermalMultiStart start_types.
PowerSystems.get_status — Methodget_status(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart status.
PowerSystems.get_time_at_status — Methodget_time_at_status(value::ThermalMultiStart) -> Float64
Get ThermalMultiStart time_at_status.
PowerSystems.get_time_limits — Methodget_time_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
Get ThermalMultiStart time_limits.
PowerSystems.set_active_power! — Methodset_active_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart active_power.
PowerSystems.set_active_power_limits! — Methodset_active_power_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart active_power_limits.
PowerSystems.set_available! — Methodset_available!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart available.
PowerSystems.set_base_power! — Methodset_base_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart base_power.
PowerSystems.set_bus! — Methodset_bus!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart bus.
PowerSystems.set_ext! — Methodset_ext!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart ext.
PowerSystems.set_fuel! — Methodset_fuel!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart fuel.
PowerSystems.set_must_run! — Methodset_must_run!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart must_run.
PowerSystems.set_operation_cost! — Methodset_operation_cost!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart operation_cost.
PowerSystems.set_power_trajectory! — Methodset_power_trajectory!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart power_trajectory.
PowerSystems.set_prime_mover! — Methodset_prime_mover!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart prime_mover.
PowerSystems.set_ramp_limits! — Methodset_ramp_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart ramp_limits.
PowerSystems.set_rating! — Methodset_rating!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart rating.
PowerSystems.set_reactive_power! — Methodset_reactive_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart reactive_power.
PowerSystems.set_reactive_power_limits! — Methodset_reactive_power_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart reactive_power_limits.
PowerSystems.set_services! — Methodset_services!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart services.
PowerSystems.set_start_time_limits! — Methodset_start_time_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart start_time_limits.
PowerSystems.set_start_types! — Methodset_start_types!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart start_types.
PowerSystems.set_status! — Methodset_status!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart status.
PowerSystems.set_time_at_status! — Methodset_time_at_status!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart time_at_status.
PowerSystems.set_time_limits! — Methodset_time_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart time_limits.
PowerSystems.set_time_series_container! — Methodset_time_series_container!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart time_series_container.