ThermalMultiStart
PowerSystems.ThermalMultiStart
— Typemutable struct ThermalMultiStart <: ThermalGen
name::String
available::Bool
status::Bool
bus::Bus
active_power::Float64
reactive_power::Float64
rating::Float64
prime_mover::PrimeMovers
fuel::ThermalFuels
active_power_limits::NamedTuple{(:min, :max), Tuple{Float64, Float64}}
reactive_power_limits::Union{Nothing, Min_Max}
ramp_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
power_trajectory::Union{Nothing, NamedTuple{(:startup, :shutdown), Tuple{Float64, Float64}}}
time_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
start_time_limits::Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}
start_types::Int
operation_cost::OperationalCost
base_power::Float64
services::Vector{Service}
time_at_status::Float64
must_run::Bool
dynamic_injector::Union{Nothing, DynamicInjection}
ext::Dict{String, Any}
time_series_container::InfrastructureSystems.TimeSeriesContainer
internal::InfrastructureSystemsInternal
end
Data Structure for thermal generation technologies.
Arguments
name::String
available::Bool
status::Bool
bus::Bus
active_power::Float64
, validation range:active_power_limits
, action if invalid:warn
reactive_power::Float64
, validation range:reactive_power_limits
, action if invalid:warn
rating::Float64
: Thermal limited MVA Power Output of the unit. <= Capacity, validation range:(0, nothing)
, action if invalid:error
prime_mover::PrimeMovers
: Prime mover technology according to EIA 923fuel::ThermalFuels
: Prime mover fuel according to EIA 923active_power_limits::NamedTuple{(:min, :max), Tuple{Float64, Float64}}
reactive_power_limits::Union{Nothing, Min_Max}
ramp_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
, validation range:(0, nothing)
, action if invalid:error
power_trajectory::Union{Nothing, NamedTuple{(:startup, :shutdown), Tuple{Float64, Float64}}}
: Power trajectory the unit will take during the start-up and shut-down ramp process, validation range:(0, nothing)
, action if invalid:error
time_limits::Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
: Minimum up and Minimum down time limits in hours, validation range:(0, nothing)
, action if invalid:error
start_time_limits::Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}
: Time limits for start-up based on turbine temperature in hoursstart_types::Int
: Number of start-up based on turbine temperature, validation range:(1, 3)
, action if invalid:error
operation_cost::OperationalCost
base_power::Float64
: Base power of the unit in MVA, validation range:(0, nothing)
, action if invalid:warn
services::Vector{Service}
: Services that this device contributes totime_at_status::Float64
must_run::Bool
dynamic_injector::Union{Nothing, DynamicInjection}
: corresponding dynamic injection deviceext::Dict{String, Any}
time_series_container::InfrastructureSystems.TimeSeriesContainer
: internal time_series storageinternal::InfrastructureSystemsInternal
: power system internal reference, do not modify
InfrastructureSystems.get_name
— Methodget_name(value::ThermalMultiStart) -> String
Get ThermalMultiStart
name
.
InfrastructureSystems.get_time_series_container
— Methodget_time_series_container(value::ThermalMultiStart) -> InfrastructureSystems.TimeSeriesContainer
Get ThermalMultiStart
time_series_container
.
InfrastructureSystems.set_name!
— Methodset_name!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
name
.
PowerSystems.get_active_power
— Methodget_active_power(value::ThermalMultiStart) -> Any
Get ThermalMultiStart
active_power
.
PowerSystems.get_active_power_limits
— Methodget_active_power_limits(value::ThermalMultiStart) -> NamedTuple{(:min, :max), _A} where _A<:Tuple{Any, Any}
Get ThermalMultiStart
active_power_limits
.
PowerSystems.get_available
— Methodget_available(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart
available
.
PowerSystems.get_base_power
— Methodget_base_power(value::ThermalMultiStart) -> Float64
Get ThermalMultiStart
base_power
.
PowerSystems.get_bus
— Methodget_bus(value::ThermalMultiStart) -> Bus
Get ThermalMultiStart
bus
.
PowerSystems.get_dynamic_injector
— Methodget_dynamic_injector(value::ThermalMultiStart) -> Union{Nothing, DynamicInjection}
Get ThermalMultiStart
dynamic_injector
.
PowerSystems.get_ext
— Methodget_ext(value::ThermalMultiStart) -> Dict{String, Any}
Get ThermalMultiStart
ext
.
PowerSystems.get_fuel
— Methodget_fuel(value::ThermalMultiStart) -> ThermalFuels
Get ThermalMultiStart
fuel
.
PowerSystems.get_must_run
— Methodget_must_run(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart
must_run
.
PowerSystems.get_operation_cost
— Methodget_operation_cost(value::ThermalMultiStart) -> PowerSystems.OperationalCost
Get ThermalMultiStart
operation_cost
.
PowerSystems.get_power_trajectory
— Methodget_power_trajectory(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:startup, :shutdown), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart
power_trajectory
.
PowerSystems.get_prime_mover
— Methodget_prime_mover(value::ThermalMultiStart) -> PrimeMovers
Get ThermalMultiStart
prime_mover
.
PowerSystems.get_ramp_limits
— Methodget_ramp_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:up, :down), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart
ramp_limits
.
PowerSystems.get_rating
— Methodget_rating(value::ThermalMultiStart) -> Any
Get ThermalMultiStart
rating
.
PowerSystems.get_reactive_power
— Methodget_reactive_power(value::ThermalMultiStart) -> Any
Get ThermalMultiStart
reactive_power
.
PowerSystems.get_reactive_power_limits
— Methodget_reactive_power_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:min, :max), _A} where _A<:Tuple{Any, Any}}
Get ThermalMultiStart
reactive_power_limits
.
PowerSystems.get_services
— Methodget_services(value::ThermalMultiStart) -> Vector{Service}
Get ThermalMultiStart
services
.
PowerSystems.get_start_time_limits
— Methodget_start_time_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:hot, :warm, :cold), Tuple{Float64, Float64, Float64}}}
Get ThermalMultiStart
start_time_limits
.
PowerSystems.get_start_types
— Methodget_start_types(value::ThermalMultiStart) -> Int64
Get ThermalMultiStart
start_types
.
PowerSystems.get_status
— Methodget_status(value::ThermalMultiStart) -> Bool
Get ThermalMultiStart
status
.
PowerSystems.get_time_at_status
— Methodget_time_at_status(value::ThermalMultiStart) -> Float64
Get ThermalMultiStart
time_at_status
.
PowerSystems.get_time_limits
— Methodget_time_limits(value::ThermalMultiStart) -> Union{Nothing, NamedTuple{(:up, :down), Tuple{Float64, Float64}}}
Get ThermalMultiStart
time_limits
.
PowerSystems.set_active_power!
— Methodset_active_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
active_power
.
PowerSystems.set_active_power_limits!
— Methodset_active_power_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
active_power_limits
.
PowerSystems.set_available!
— Methodset_available!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
available
.
PowerSystems.set_base_power!
— Methodset_base_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
base_power
.
PowerSystems.set_bus!
— Methodset_bus!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
bus
.
PowerSystems.set_ext!
— Methodset_ext!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
ext
.
PowerSystems.set_fuel!
— Methodset_fuel!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
fuel
.
PowerSystems.set_must_run!
— Methodset_must_run!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
must_run
.
PowerSystems.set_operation_cost!
— Methodset_operation_cost!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
operation_cost
.
PowerSystems.set_power_trajectory!
— Methodset_power_trajectory!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
power_trajectory
.
PowerSystems.set_prime_mover!
— Methodset_prime_mover!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
prime_mover
.
PowerSystems.set_ramp_limits!
— Methodset_ramp_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
ramp_limits
.
PowerSystems.set_rating!
— Methodset_rating!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
rating
.
PowerSystems.set_reactive_power!
— Methodset_reactive_power!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
reactive_power
.
PowerSystems.set_reactive_power_limits!
— Methodset_reactive_power_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
reactive_power_limits
.
PowerSystems.set_services!
— Methodset_services!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
services
.
PowerSystems.set_start_time_limits!
— Methodset_start_time_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
start_time_limits
.
PowerSystems.set_start_types!
— Methodset_start_types!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
start_types
.
PowerSystems.set_status!
— Methodset_status!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
status
.
PowerSystems.set_time_at_status!
— Methodset_time_at_status!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
time_at_status
.
PowerSystems.set_time_limits!
— Methodset_time_limits!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
time_limits
.
PowerSystems.set_time_series_container!
— Methodset_time_series_container!(value::ThermalMultiStart, val) -> Any
Set ThermalMultiStart
time_series_container
.